1.Introducing an innovative track inspection instrument, a state-of-the-art track geometry status inspection device. Built on the precise angular measurement principle using fiber optic gyroscope trajectory measurement, it ensures unparalleled precision. The system is powered by a robust notebook computer, meticulously adapted for rigorous field operations, serving as the data processing hub. Enjoy real-time data and waveform displays, complete with advanced online over-limit alarms for comprehensive monitoring of all parameters. zmwm14
2.For high-speed lines, ≤350 km/h, rely on our premium Level 0 track inspection instrument for ultimate precision.
For medium-speed lines, ≤200 km/h, our Level 1 track inspection instrument delivers reliability and accuracy.
3.Achieve precision with a recommended travel speed of 4km/h, and a uniform speed of ≤ 8km/h.
Operates efficiently with a supply voltage of 14.4V±1.5, ensuring stable performance.
Features a remarkable sampling spacing of 0.125m, capturing 8 data points per meter for detailed analysis.
Compact yet robust design: Overall dimensions (L×W×H) of 1600mm×850mm×235mm.
Equipped with a high-performance lithium battery, rated voltage at 14.4v.
Rated capacity stands at an impressive 8Ah, delivering sustained energy for extended operations.
Lightweight and portable with a weight of approximately 32kg, facilitating ease of transport and handling.
4. Comprehensive Track Inspection Instrument Detection Items:
- Gauge - Ensuring exact rail width measurements.
- Track Gauge Variation Rate - Monitoring the uniformity over distances.
- Cross level (Superelevation) - Assessing the incline for safety and comfort.
- Track twist - Detecting torsional deformities for structural integrity.
- Longitudinal level (Vertical profile) - Ensuring smooth vertical alignment.
- Alignment (Lateral alignment) - Maintaining lateral rail precision.
- Versine - Measuring deviations for reliable track geometry.
- Mileage - Accurate tracking of distance for comprehensive analysis.


Project |
Allowableerror (tolerance) |
gauge |
|
Level0 |
Level1 |
Zero Position Accuracy Indication Error |
±0.15 |
±0.15 |
Measurement Repeatabity |
±0.30 |
±0.50 |
≤0.15 |
≤0.20 |
Indication Error |
≤0.45 ±0.02% |
≤0.75 |
Gauge change rate |
Measurement Repeatability |
≤ 0.03% |
±0.03% ≤0.045% |
Zero Point Accuracy |
±0.15 |
|
Superelevation |
Indication Error |
|
±0.15 |
Reversal Error |
±0.30 ≤0.30 |
±0.50 |
|
≤0.15 |
≤0.30 ≤0.20 |
Measurementrepeatability |
≤0.45 |
≤0.75 |