1.Introducing our state-of-the-art track inspection instrument—a beacon of precision in the realm of track geometry status inspection! Utilizing the cutting-edge principle of fiber optic gyroscope trajectory measurement, this device stands as a testament to accuracy and reliability. Featuring a robust notebook computer designed for field operations, it serves as the dynamic data processing center, empowering you with real-time data and waveform displays. Be assured of safety and precision with its capability to deliver instantaneous over-limit alarms for all parameters, ensuring optimal track performance.zmwm14
2.Specifically engineered for lines with a speed limit of up to 350 km/h, our Level 0 track inspection instrument is the epitome of high-speed safety and efficiency.
Catering to lines with a speed limit of up to 200 km/h, our Level 1 track inspection instrument provides reliable and precise evaluations for moderate-speed railways.
3.Travel speed: maintain a consistent pace ≤ 8km/h, with 4km/h as the optimal recommendation for best performance.
Supply voltage: A stable and consistent 14.4V±1.5 ensures uninterrupted operation.
Sampling spacing: Achieve meticulous measurements with a spacing of 0.125m, capturing 8 precision points per meter.
Overall dimensions (L×W×H): Efficient design with compactness at 1600mm×850mm×235mm, ensuring ease of use and transport.
Lithium battery: Experience the power of a 14.4v rated voltage, ensuring enhanced endurance and reliability.
Rated capacity: 8Ah, providing you with extended periods of operation for comprehensive inspections.
Weight: Approximately 32kg, combining portability with sturdiness for field operations.
4. Track inspection instrument detection items:
- Gauge
- Track Gauge Variation Rate
- Cross level (Superelevation)
- Track twist
- Longitudinal level (Vertical profile)
- Alignment (Lateral alignment)
- Versine
- Mileage


Project |
Allowableerror (tolerance) |
gauge |
|
Level0 |
Level1 |
Zero Position Accuracy Indication Error |
±0.15 |
±0.15 |
Measurement Repeatabity |
±0.30 |
±0.50 |
≤0.15 |
≤0.20 |
Indication Error |
≤0.45 ±0.02% |
≤0.75 |
Gauge change rate |
Measurement Repeatability |
≤ 0.03% |
±0.03% ≤0.045% |
Zero Point Accuracy |
±0.15 |
|
Superelevation |
Indication Error |
|
±0.15 |
Reversal Error |
±0.30 ≤0.30 |
±0.50 |
|
≤0.15 |
≤0.30 ≤0.20 |
Measurementrepeatability |
≤0.45 |
≤0.75 |